Issue
Borland errors are usually seen if the Borland database is configured incorrectly. It is seldom seen on Windows XP, but more often seen on Windows 7 machines. If you do see these messages in Windows XP, the following fix will also apply. When the following database changes are done in the Database Administrator, the system should not have any errors.
Firstly ensure you are logged in as an Administrator
Go to Start > All Programs >TITAN Security System > Database Administrator.
Go to Configuration > Drivers > Native > Paradox. Change the values to the red boxes below.
(Note: Windows 64-bit users will need to set the NET DIR path to "C:\Program Files (x86)\Tecom\Bin")
Go to System > INIT. Change SHAREDMEMLOCATION to 5bde
Finally save your changes by going to Object > Apply.
Restart you PC and restart Titan.