Challenger 10 Firmware Update (V10-04-4479)
Warning: This update requires a Minimum of:
Challenger 10 Firmware Update (V10-02-3605) and Bootloader 3433 to be loaded <<<Contact Technical Support Team to get this version...
To Apply this firmware:
This Update can be loaded via Titan 3.2 or above. <<<Contact Technical Support Team to get this version...
This Update can also be loaded via the fimware loader software <<<Contact Technical Support Team to get this software tool...
New Features:
Decrement test days during TZ. When using automated input testing you can assign a time zone in order to specify which days the system uses to check whether inputs have been tested. This stops inputs false reporting test failures on weekends or when businesses are not open.
Reset input test days. After programming automated input testing you can reset the input timer before handing the system over.
Resolved issues:
If arming was attempted with an unsealed input and a user category timer running, then arming would fail and the user category would be canceled.
Floor groups were not working when assigned to a user.
Could not arm the area if two user categories were running on the same area.
Known Issues:
Comm path format Securitel STU, sub-format None, sends system alarms when system alarms report is disabled.
Report fail message state is cleared when path queue is cleared.
A dialler path could have an incorrect number of retries.
Comm path priorities functionality is not yet supported.
Only two levels of backup path are supported in addition to the primary path (three paths in total).
We do not recommend using one type of path format to backup a different type of path format (for example, using a CID Dialler path as a backup for Management Software path).
DVR time and date synchronisation is not supported in this release.
On a wireless DGP, input numbers displayed on an LCD RAS are incorrect for any DGP address higher than DGP 1. This issue affects only the display of input numbers via LCD RAS when programming a WDGP. The reporting of WDGP inputs to the Challenger10 panel is not affected.
How to install:
This is the first firmware to be installed directly from Titan.
Download the Challenger10_pcb1020_V10-04-4479.zip file and do NOT unzip.
To install this update open Titan 3.2 and connect to your Challenger 10.
- Control>Firmware Upgrade>Warning>OK.
- Press the Recall button to ensure you have V10-02-3605 loaded (May flash quickly)
- Press Browse button and navigate to location of 3951firmware zip.
- Press Download/Upgrade and wait.
After the download progress bar has reached 100% you can close the firmware upgrade menu.
Your Challenger 10 should automatically reconnect to Titan after a few minutes (you must exit the firmware upgrade menu to reconnect)